30 BITUMEN DRUM MELTING UNIT

TECHNICAL SPECIFICATIONS 

MAIN FEATURES: 

  • 3x10 = 30 drums capacity in drum section.
  • 6.000 - 9.000 kg capacity according to ambient temperature & working conditions.
  • Hydraulic lift able stand to load drums upside-down into melting unit.
  • Hydraulic cylinder to drive the lifting stand-2nos.
  • Hydraulic pumping unit-1no.
  • Bitumen transfer& 6m piping up to bitumen tank-1no.

a)   GENERAL DESCRIPTION

Capacity :
  • 3 x 10 drum/h x 200 kg/drum 6.000 kg/h (bitumen at 110°C, capacity may vary due to operating conditions;  bitumen penetration,  ambient  temperature,  drum loading capacity staff and machinery)
Drum loading mechanism : W1750 xL7300xH2250(Approx)
Dimensions : Hydraulically actuated
Heating method : Thermic Fluid
Required thermal capacity : 500.000kCal/h (Not Included)


b) MELTING UNIT DRUM PASSAGES

Capacity : 3 x 10 drums
Heating coil surface area : 43m²
Heating coil pipes : Ø 60,3 x 3,6 mm, DIN 2448, seamless steel pipes
Insulation : 50mm, 80kg/m³
Insulation cladding : 1mm aluminium
Paint : High temperature resistant aluminium silicon paint

 

c)    BOTTOM RESERVOIR (TANK)

Capacity : 15.000 lt
Heating coil surface area : 22m²
Heating coil pipes : Ø 60,3 x 3,6 mm, DIN 2448, seamless steel pipes
Insulation : 50mm, 80kg/m³
Insulation cladding : 1mm aluminium/GI
Paint : High temperature heat resistant paint


d)   BITUMEN PUMP

Type : Gear type, specially designed compact, positive displacement, gear type bitumen pump
Capacity : 30m³/h
Motor power : 10HP
Maximum pressure : 6bar


e)   HYDRAULIC SYSTEM

Pumping unit : 5HP
Hydraulic cylinders : 2x HCD 250
Control system : Manual valve control


f)     ACCESSORIES & OTHER EQUIPMENTS

  • No.1 DN80 bitumen valve
  • 6m bitumen pipe
  • No.2 DN65 hot oil valve
  • No.1 minimum level switch

Clientele